EVI Air Source heat pumps Low temp
MODEL | | JTT-10L | JTT-17II/L | JTT-35II/L | JTT-70II/L |
Hot water capacity | kW | 10.30 | 17.80 | 37.40 | 69.80 |
COP in Hot Water (A9/A19) Refer row 40 | | 4.44 | 4.43 | 4.41 | 4.58 |
Rise in water Temp required | °C | 40 °C |
Hot water output under recirculations | L/h | 295 Liters/Hour | 510 Liters/Hour | 1072 Liters/Hour | 2001 Liters/Hour |
Rated outlet water Temp. | °C | 55 °C |
Max outlet water Temp. | °C | 60 °C |
Space Heating capacity water (in/out):35℃/40℃ | kW | 8.2 | 14.6 | 28.7 | 57.4 |
COP Space Heating (A15/A19) Refer row 54 | | 3.53 | 3.63 | 3.38 | 3.77 |
Space Heating capacity water (in/out):40℃/45℃ | kW | 8.2 | 14.6 | 28.7 | 57.4 |
COP Space Heating (A17/A19) Refer row 55 | | 3.53 | 3.63 | 3.38 | 3.77 |
Rated power input | Kwh | 2.32 | 4.02 | 8.48 | 15.23 |
Rated current | A | 11.10 | 7.63 | 16.11 | 28.93 |
Power supply | V/Hz/Ph | 220~240/1/50 | 380~415/3/50 |
Compressor type | | Copeland Scroll |
Number of Compressors | | 1 | 1 | 2 | 2 |
Heat exchanger type | | High efficiency tube intube heat exchanger |
Throttling device | | Emerson thermal expansion valve |
Condensor Fan type | | Low noise high effciency axial type |
Condensor Fan discharging | | Vertical |
Condensor Fan quantity | | 1 | 1 | 2 | 2 |
Condensor Fan input power | W | 70 | 250 | 250 | 750 |
Condensor Fan speed | RPM | 850 | 880 | 850 | 940 |
Ambient temperature | ℃ | (-25℃~+43℃) |
Refrigerant | | R407C/R417A |
Noise in 1 meter distance | dB | 59 | 62 | 63 | 68 |
Water pipe size | inch | R1 | R1 | R1-1/2 | Rc2-1/2 |
PLC Controller | | Yes Digital LCD Controller |
Daily 2 set of programmes for On / Off | | Yes | Yes | Yes | Yes |
Compressor Low / High pressure protection | | Yes | Yes | Yes | Yes |
Compressor protection water flow switch | | Yes | Yes | Yes | Yes |
Compressor Overload Protection Switch | | Yes | Yes | Yes | Yes |
Compressor time delay protection | | Yes | Yes | Yes | Yes |
Sequential Phase & Missing Phase protection | | Yes | Yes | Yes | Yes |
Automatical defrost system | | Yes | Yes | Yes | Yes |
Water Tank temp sensor & its error detection | | Yes | Yes | Yes | Yes |
Outlet hot water temp sensor & its error detection | | Yes | Yes | Yes | Yes |
Inlet water temp sensor & its error detection | | Yes | Yes | Yes | Yes |
Ambient air temp sensor & its error detection | | Yes | Yes | Yes | Yes |
Controller Communications failure | | Yes | Yes | Yes | Yes |
Testing condition for Hot Water | Heating:Ambient temp. (DB/WB):20℃/15℃, water temp. (input/output):15℃/55℃ | |
Testing condition for Space Heating | Heating:Ambient temp. (DB/WB):7℃/6℃, water temp. (input/output):35℃/40℃ | |
Testing condition for Space Heating | Heating:Ambient temp. (DB/WB):7℃/6℃, water temp. (input/output):40℃/45℃ | |
EVI Air Source heat pumps transfer heat from the ambient air to water, providing high-temperature hot water up to 60°C. The unique Low ambient-temp heat pump is widely used for house warming. With innovative & advanced technology, the direct-heating heat pump can operate very well at -25℃ ambient temperature with high output temperatures up to 60℃, which ensures the compatibility with normal sized radiator based systems without supplementation. Compared with traditional oil/LPG boilers, high-temperature heat pump produces up to 50% less CO2 whilst saves 80% running cost.