2017 new EVI monoblock air to water heat pump with refrigerant R407c R410A heat pump
Juteng air source heat pump reliable Components for EVI heat pmp
1. WHOLE HOUSING metiral: Stainless steel anti corrosion and rustproof
2. World famous brand Copleand Compressor with Eco-Friendly Refrigerant R407c/R410A/R22
3. Copper Tube-in-Shell Water Heat Exchanger (Condenser)
4. Hydrophilic Aluminum Fin-Tube Air Heat Exchanger (Evaporator)
5. Japanese Brand Sanhua 4-Way Valve and Sanhua electronic expansion valve
6. Remote LCD Controller
Real product show
EVI parameter
EVI special compressor AIR SOURCE HEAT PUMP(COLD WATER) UNIT specification |
Model No. | JT3.0SID | JT5.0SID | JT6.0SID | JT8.0SID |
Rated cooling capacity /COP | DB35W7 | 7.28KW/2.8 | DB35W7 | 12.5KW/2.7 | DB35W7 | 15.1KW/2.8 | DB35W7 | 18.2KW/2.8 |
Rated heating capacity/COP | DB-12W41 | 4.62KW/2.1 | DB-12W41 | 8.7KW/2.1 | DB-12W41 | 10.9KW/2.1 | DB-12W41 | 14.49KW/2.1 |
Heating capacity in low temperature/COP | DB-20W41 | 4.54KW/1.65 | DB-20W41 | 6.89KW/1.65 | DB-20W41 | 8.1KW/1.65 | DB-20W41 | 11.3KW/1.65 |
IPLV(C) | 2.7 | 2.7 | 2.7 | 2.7 |
IPLV(H) | 2.4 | 2.4 | 2.4 | 2.4 |
Rated cooling input power | 2.6KW | 4.48KW | 5.4KW | 7.1KW |
Rated heating input power | 2.2KW | 4.18KW | 5.2KW | 6.9KW |
Max input power | 3.3KW | 6.0KW | 6.6KW | 6.6KW |
Cooling input current | 11A | 20A | 24.5A | 34A |
Heating input current | 10A | 24A | 28A | 32A |
Max input current | 15A | 28A | 30A | 36A |
Voltage/Frequency | 220V 1N~/50Hz | 220V 1N~/50Hz | 220V 1N~/50Hz | 220V 1N~/50Hz |
Refrigerant/qty | 3500g | 407C | 4800g | R22 | 5800g | 407C | 4650g*2 |
Nosie level | ≤60Db(A) | ≤65Db(A) | ≤65Db(A) | ≤68Db(A) |
Protection level | IPX4/ I | IPX4/ I | IPX4/ I | IPX4/ I |
Cooling water temperature | 5~15℃ | 5~15℃ | 5~15℃ | 5~15℃ |
Heating hot water temperature | 30~60℃ | 30~60℃ | 30~60℃ | 30~60℃ |
Air-out max pressure | 3.0Mpa | 3.0Mpa | 3.0Mpa | 3.0Mpa |
Air-in max pressure | 0.8Mpa | 0.8Mpa | 0.8Mpa | 0.8Mpa |
Water flow | 820L/H | 1500L/H | 1880L/H | 2492L/H |
Water side pressure loss | ≤35Kpa | ≤35Kpa | ≤35Kpa | ≤35Kpa |
Water flow pressure drop | 0.01-0.02 Mpa | 0.01-0.02 Mpa | 0.01-0.02 Mpa | 0.01-0.02 Mpa |
Working ambient temperature | -25℃~43℃ | -25℃~43℃ | -25℃~43℃ | -25℃~43℃ |
Dimension | 717×717×930(mm) | 1300×650×930(mm) | 1300×650×10330(mm) | 1424×717×960(mm) |
Weight | 105Kg | 135Kg | 148Kg | 210Kg |
Remark | 1.Above datas were checked according to GB/T18430.2-2008,GB/T21362-2008,GB/4706.1,GB/4706.32,GB/4706.12,GB/4343.1,GB25127.2-2010 GB/17625.1 working condition. 2.Working condition cooling mode water flow 0.172m³/(hkW),temperature of chilled water outlet 12℃/7℃,ambient temperature 35℃/24℃.3,Working condition cooling mode water flow 0.172m³/(hkW),temperature of hotwater outlet 36℃/41℃,ambient temperature -12℃ |
EVI special compressor AIR SOURCE HEAT PUMP(COLD WATER) UNIT specification |
Model No. | JT10.0SID | JT15.0SID | JT20.0SID | JT25.0SID |
Rated cooling capacity /COP | DB35W7 | 24.9KW/2.8 | DB35W7 | 35.8KW/2.8 | DB35W7 | 50KW/2.8 | DB35W7 | 65KW/2.8 |
Rated heating capacity/COP | DB-12W41 | 17.2KW/2.1 | DB-12W41 | 26KW/2.1 | DB-12W41 | 34.65KW/2.1 | DB-12W41 | 45.1KW/2.1 |
Heating capacity in low temperature/COP | DB-20W41 | 13.5KW/1.65 | DB-20W41 | 20.2KW/1.6 | DB-20W41 | 27.2KW/1.65 | DB-20W41 | 39.5KW/1.65 |
IPLV(C) | 2.7 | 2.7 | 2.7 | 2.7 |
IPLV(H) | 2.4 | 2.4 | 2.4 | 2.4 |
Rated cooling input power | 8.9KW | 12.8KW | 17.8KW | 23.2KW |
Rated heating input power | 8.2KW | 12.5KW | 16.5KW | 21.5KW |
Max input power | 10.2KW | 10.2KW | 21.3KW | 27.5KW |
Cooling input current | 12.8A | 12.8A | 32A | 38A |
Heating input current | 11.3A | 19A | 30A | 36A |
Max input current | 15A | 22A | 38A | 43A |
Voltage/Frequency | 380V 1N~/50Hz | 380V 1N~/50Hz | 380V 1N~/50Hz | 380V 1N~/50Hz |
Refrigerant/qty | 407C | 4800g*2 | R22 | 6200g*2 | R407C | 10500g*2 | R22 | 11500g*2 |
Nosie level | ≤68Db(A) | ≤68Db(A) | ≤68Db(A) | ≤68Db(A) |
Protection level | IPX4/ I | IPX4/ I | IPX4/ I | IPX4/ I |
Cooling water temperature | 5~15℃ | 5~15℃ | 5~15℃ | 5~15℃ |
Heating hot water temperature | 30~60℃ | 30~60℃ | 30~60℃ | 30~60℃ |
Air-out max pressure | 3.0Mpa | 3.0Mpa | 3.0Mpa | 3.0Mpa |
Air-in max pressure | 0.8Mpa | 0.8Mpa | 0.8Mpa | 0.8Mpa |
Water flow | 2961L/H | 4515L/H | 4239L/H | 7757L/H |
Water side pressure loss | ≤35Kpa | ≤35Kpa | ≤35Kpa | ≤35Kpa |
Water flow pressure drop | 0.01-0.02 Mpa | 0.01-0.02 Mpa | 0.01-0.02 Mpa | 0.01-0.02 Mpa |
Working ambient temperature | -25℃~43℃ | -25℃~43℃ | -25℃~43℃ | -25℃~43℃ |
Dimension | 1424×717×960(mm) | 1600×805×960(mm) | 2000×1100×1860(mm) | 2000×1100×1860(mm) |
Weight | 105Kg | 135Kg | 148Kg | 210Kg |
Remark | 1.Above datas were checked according to GB/T18430.2-2008,GB/T21362-2008,GB/4706.1,GB/4706.32,GB/4706.12,GB/4343.1,GB25127.2-2010 GB/17625.1 working condition. 2.Working condition cooling mode water flow 0.172m³/(hkW),temperature of chilled water outlet 12℃/7℃,ambient temperature 35℃/24℃.3,Working condition cooling mode water flow 0.172m³/(hkW),temperature of hotwater outlet 36℃/41℃,ambient temperature -12℃ |
Company Information
Guangdong Ju Teng environmental equipmental Co; Ltd builded in 2000 is a high-tech company which produces new enery and high effeciant environmental protection. This company, relying on, such as his funds, Technology, human resources, information, is built as develop system which contains Multifunctional Comprehensive lab, high-tech research room and Performance Evaluation room. The factory has built up two product bases in Nahai Foshan. One is air recourse Pumps, the other being tank, At present, the company, owing deparments such as pumps technology development, Electric conformity Tank, home hteat pumps, welding, assembly, detection, is one of the top manufacturer which has a complete product chain.
The factory has passed ISO9001,CCC,CE,TUV and international standard product certification.
High quality products, best service, competitive price, so that gainning good faiths from clients all over the world.
Advantages
1. We are the leader manufacture of air source heat pump of China.
2. We will have many new styles, and we can customized follow your design.
3. We have the factory, can visit the factory at any time.
4. We can control the quality of products.
5. All of our products pass the certificate(CE or CCC or TUV)
6. Our products "high efficiency" "energy saving" "environmental".
7. We have our own factory, we are advantage at high quality with good price.
Our Services
1. We would reply you soon as we can within 24hours.
2. We would follow your orders and inform you status at least every 2 days!
3. After your orders, our sales would follow the shippping till to you received it.
4. We would send you information about our new products or promotional activity.
5. We would offer professional advice to install after your purchased.
Contact
Ms. Laura
Company:Guangdong Juteng Environmental Protection Equipment Co.,ltd.
Add: Longchuan Dengyun Zhen Shenzhen Nanshan(Longchuan) industrial transfer park,Heyuan Guangdong China
Tel: (86 762) 6588888; Fax: (86 762) 6588889
Cell/Whatsapp/Wechat: +86
Skype: luara.na
Email:laura at gdjuteng.com