Air source Multifunctional Juteng Heat Pump trinity for heating, cooling and free hot water with High COP, EER
Working Principle:
Compressor gets the low temperature and low pressure air refrigerant from evaporator,
then turn it into high temperature and high pressure air,
this air gets into the condenser to exchange the heat with water,
then the condensed air become low temperature fluid and release lots of heat energy.
Water gets this heat energy and become hotter and hotter.
This high pressure and low temperature fluid become low pressure by the primary flow meter device.
This low pressure and low temperature fluid, gets into the evaporator, Under the function of rotation fan, heat energy from air is absorbed by the fluid and becomes low pressure refrigerant,
then is absorbed by compressor, recycling to produce the hot water.
Product Description
Model | | DKFXJT-3.0-11.2II/MWFR | LSQ-5HJ/MWFR |
Horse power | HP | 3 | 5 |
Heating or cooling Capacity | | Heating | Cooling | Heating | Cooling |
Capacity | kW | 8 | 7.5 | 14.7 | 12.5 |
Power Input | kW | 2.4 | 2.5 | 4.2 | 4.6 |
Current Input | A | 15.00 | 16.00 | 8.60 | 9.20 |
Heating COP or Cooling EER | | 3.33 | 3.00 | 3.50 | 2.72 |
Rated Voltage / frequency | V/Hz | 220-240/50 | 380-415V/50Hz/3Ph |
Max Power Input | kW | 2.88 | 3 | 5.04 | 5.52 |
Max Current | A | 18 | 19.2 | 10.32 | 11.04 |
Rated hot water output | L/H | 230 | 430 |
COP in Heating 40℃/45℃ at 7℃/6℃ ambient temp. | | 3.32 | - | 3.35 | - |
COP in Cooling 12℃/7℃ at 35℃/24℃ ambient temp. | | - | 2.85 | - | 2.89 |
Refrigerant type / Charge | … / kg | R22 or R410A / 2.2 | R22 or R410A / 4 |
Water connections | inch | 1 | 1 |
Heating / Cooling Water pipe connection diameter | inch | 16 | 19 |
Supplementary heater vessel (not bulit-in) | L | 10 | 10 |
Hot water circulation flow | m³/h | 3 | 5 |
Water side pressure loss | kPa | 35 | 35 |
Water flow pressure drop | Mpa | 0.01-0.02 | 0.01-0.02 |
Suction/discharge max pressure | Mpa | 0.8 / 2.8 | 0.8 / 2.8 |
Unit protection class | IP | IPX4 | IPX4 |
Anti-electric shock class | | Glass 1 | Glass 1 |
Operating in Ambient temp. | ℃ | (-15℃~45℃) | (-15℃~45℃) |
Hot water outlet temp | ℃ | 55~60 |
Cool water outlet temp | | 7/12℃ |
Sound pressure level (1m) | dB (A) | 50 | 65 |
PLC Controller | | Yes Digital LCD Controller |
Net weight(Top/side type) | kg | 88 / 80 | 125 / 130 |
Net dimension(Top type) | mm | 717x717x860=0.44m³ | 717x717x960=0.49m³ |
Net dimension(Side type) | mm | 750x340x1200=0.31m³ | 920x390x1200=0.43m³ |
Capacity and power input based on the GB/T18430.2-2008,GB/T21362-2008 conditions:
Heating mode: Water flow 0.172m³/(hkW), hot water outlet temp. 45℃, ambiemt temp. (DB/WB) 7/6℃
Cooling mode: Water flow 0.172m³/(hkW), cold water outlet temp. 7℃, ambiemt temp. 35℃
Hot water mode: Water flow 0.172m³/(hkW), hot water inlet/outlet temp. 15/55℃, ambiemt temp. (DB/WB) 20/15℃
Our Services
Main quality control project list:
1. Check all parts before assembling.
2. Charge nitrogen to test leakage and pressure maintaining after welding system.
3. Vacuumize, the vacuum pressure ≤30Pa
4. Leakage detection by halogen after charge refrigerant.
5. Safety testing: High-voltage insulation test and ground resistance.
6. Operation testing, record refrigerant pressure, temp. etc.
7. Inspect inside unit’s cleanliness and appearance.
PRODUCTION PROCESS of HEAT PUMP
1. Base plates go online
2. Install compressors, condensers and evaporators
3. Assemble and weld copper pipes
4. Recharged with Nitrogen
5. Water-inspection
6. Discharge Nitrogen
7. Vacuum air-removed
8. Add refrigerant
9. Halogen inspection
10. Fix fan component
11. Install electrical control
12. Security checks
13. Run commodity inspection
14. Stick nameplate and connection diagram
15. Document attached (Product Manuals, instructions)
16. Final inspection (Appearance parts)
17. Packing
18. Tape-out